
Introduction
The NEMA 23 stepper motor is one of the most widely used actuators in motion control systems. As a medium-frame-size motor defined by the National Electrical Manufacturers Association (NEMA) standards—featuring a 2.3-inch x 2.3-inch flange—the NEMA 23 stepper motor offers a balanced combination of output torque, mounting dimensions, and cost control, making it a common choice in industrial automation equipment design.
Stepper motor selection typically revolves around torque. For NEMA 23 stepper motors, torque characteristics directly determine load capacity, acceleration/deceleration performance, and operational stability. Holding torque defines positioning stiffness at standstill, while running torque reflects the motor's actual driving capability during continuous operation. Understanding torque characteristics is essential for properly matching the motor to the mechanical load.
This article examines the torque parameters of NEMA 23 stepper motors, analyzes their performance under different operating conditions, and outlines their typical applications in industrial scenarios.
What Is a NEMA 23 Stepper Motor?
A NEMA 23 stepper motor refers to a stepper motor that conforms to National Electrical Manufacturers Association (NEMA) standards with a flange dimension of 2.3 inches × 2.3 inches (approximately 58 mm × 58 mm). This dimensional standard ensures consistency in mounting hole spacing and pilot diameter across NEMA 23 motors from different manufacturers, providing mechanical interchangeability.
In terms of specifications, typical NEMA 23 stepper motors feature body lengths (excluding shaft extension) ranging from 40 mm to 100 mm, with shaft diameters generally either 6.35 mm (1/4 inch) or 8 mm, depending on the motor's designed torque rating. The motor construction consists primarily of a stator, rotor, front and rear end bells, and an output shaft.
In-Depth Analysis of NEMA 23 Torque Characteristics
As the technical core of this article, understanding the torque characteristics of NEMA 23 stepper motors is essential for proper application and performance optimization.
Holding Torque
Holding torque refers to the maximum torque that a stepper motor can exert when the windings are energized but the rotor is stationary. It is measured in Newton-meters (N·m) or ounce-inches (oz-in), with 1 N·m approximately equal to 141.6 oz-in.
For NEMA 23 stepper motors, typical holding torque ratings range from 1.0 N·m to 3.0 N·m (approximately 140 oz-in to 425 oz-in), depending on motor length and winding configuration. Longer motor stacks accommodate more magnetic material and therefore produce higher holding torque.
Pull-in and Pull-out Torque
While holding torque describes static performance, pull-in and pull-out torque characterize dynamic behavior during motion.
Pull-in torque (also called starting torque) is the maximum load torque against which the motor can start from standstill and synchronize with a command pulse train without losing steps. It applies only when starting at a specific pulse rate.
Pull-out torque (also called running torque) is the maximum load torque the motor can drive at a given speed while remaining in synchronism. Once the load exceeds this value, the motor will stall or lose steps.
Factors Affecting Torque Output
Several operating conditions and system parameters influence the actual torque delivered by a NEMA 23 stepper motor in application.
Current and Driver Settings
Torque output is directly related to winding current. Higher current increases torque until magnetic saturation occurs. Driver voltage affects current rise time; higher supply voltages allow current to reach its set value more quickly, improving high-speed torque performance.
Load Inertia Matching
The inertia ratio between load and rotor affects acceleration capability and resonance behavior. Excessive load inertia may require longer acceleration profiles to prevent step loss.
Thermal Management
Continuous operation generates heat due to I²R losses in the windings. Heat dissipation affects maximum continuous torque capability; excessive temperature can degrade magnet performance and insulation life.
Industrial Applications of NEMA 23 Stepper Motors
The torque characteristics of NEMA 23 stepper motors make them suitable for a wide range of industrial applications.
CNC Machining and Engraving

NEMA 23 stepper motors are widely used in small to medium-sized CNC equipment, including milling machines, engraving machines, and plasma cutters.
3D Printers and Additive Manufacturing

While smaller NEMA 17 motors dominate desktop 3D printing, NEMA 23 stepper motors are increasingly specified for large-format 3D printers and high-speed additive manufacturing systems.
Robotics and Automation

In robotics and automated systems, NEMA 23 stepper motors serve in small robotic arms, SCARA robot joints, and pick-and-place units.
How to Select the Right NEMA 23 Stepper Motor Based on Torque Requirements
Selecting the appropriate NEMA 23 stepper motor for an application requires a systematic approach centered on torque analysis.
Step 1: Calculate Load Torque Requirements
The first step in NEMA 23 sizing is determining the torque needed to drive the mechanical load under worst-case operating conditions.
Step 2: Determine Operating Speed Range
Identify the speed range over which the motor must deliver torque.
Step 3: Consult the Torque-Speed Curve
With load torque and speed requirements defined, compare them against the manufacturer's torque-speed curves. The chart above illustrates a typical NEMA 23 torque attenuation characteristic, which can be used to verify whether the motor meets application requirements.
Step 4: Consider Driver and Power Supply Capabilities
Motor torque performance is inseparable from the drive electronics.
Step 5: Verify Thermal and Duty Cycle Constraints
Continuous operation generates heat that can limit actual torque output.
Need Assistance with NEMA 23 Sizing?
Torque calculation and motor selection involve multiple variables. If you need help determining the right NEMA 23 stepper motor for your specific application, our engineering team can assist.
Conclusion
NEMA 23 stepper motors deliver the torque characteristics that make them the preferred choice for medium-duty industrial applications—offering holding torque from 1.0 N·m to 3.0 N·m, predictable speed-torque performance, and compatibility with standard drivers.
Browse NEMA 23 Products – View specifications and torque curves